43
Retrieve HDD redundancy
The user can retrieve the backup recording data from redundancy HDD when the RW
HDD is damaged or data lost. Firstly, shut down DVR and remove damaged HDD, then
restart DVR;
Secondly, Get into Main menuStorage, set redundancy HDD as a reading
and writing HDD, then it can be searched.
4.6 HDD S.M.A.R.T
S.M.A.R.T (Self-Monitoring, Analysis and Reporting Technology)
S.M.A.R.T HDD can analyse the head, disc, motor, circuit operation, history and default
security values via the monitor instruction in HDD and surveillance software. An alarm
will be sent to the user automatically when the value is outside the scope of a low alert
security situation.
Detection parameters of Seagate HDD for example are divided into seven: ID detection
code, Attribute Description, Threshold, Attribute Value, Worst, Date, and Status.
1. ID detection code
The ID detection code is not always the same, the manufacturer can use different ID
code or increase/decrease its quantity according to the detected parameter’s quantity.
For example: the ID detection code of WEASTERN DIGITAL’s product is “04”, the
parameter is for Start/Stop Count, but the parameter has the same code as the Fujitsu’s
product and means: “Number of times the spindle motor is activated”.
2. Attribute Description
Attribute Description: name of detection item. Manufacturer can increase or decrease.
Because the ATA standard updates constantly, sometimes there are maybe different
models in same brand, but you must ensure that they are the same major test items
specified in S.M.A.R.T. (although different manufacturers have specific naming
convention, the essence of monitoring is the same).
1: Read Error Rate
2: Spin up Time
4: Start/Stop Count
5: Relocated Sector Count
7: Seek Error Rate
9: Power-on Hours Count
10: Spin up Retry Count
194: Power temperatures
195: ECC on the Fly count
197: Current Pending Sector Count